EMERGENCY STOP MODULE BH5903.22/00000/61 DC24V (0053092)
Emergency Stop Module with voltage failure detection BH5903. E-stop with latching function. Automatic start when voltage returns after phase failure when no E-Stop was operated before phase failure.
Application
- For plants, that should start automatically at return of voltage after phase failure. E.g. Compressor plants, water and sewage water plants.
Downloads
Technical specifications
| Manufacturer: | Dold |
| Series: | BH 5903 |
| Type: | BH5903.22/00020/61 DC24V |
| Article number: | 0053092 |
| Sales Price: | € 557,00 |
|
|
|
| Contacts: | 2 NO contacts, 1 NC contact as signal output |
| Nominal voltage: | DC 24 V |
| Approvals and Markings: | UL-listed C/US, TÜV, UKCA |
| Variant: | For 2 E-Stop loops singel channel operated |
| Common technical specifications BH 5903 | |
| Width: | 45 mm |
| Cat. / PL acc. to EN ISO 13849-1: | 4/e |
| SIL CL acc. to IEC/EN 62061: | 3 |
| Nominal voltage: | DC |
| Thermal current Ith max.: | 5 A |
| 1- / 2-channel: | 1, 2 |
| Cross fault detection: | Yes |
| Connection: | Pluggable screw terminals |
| Output contacts max.: | 3 NO contacts |
| Approvals: | UL |